Overcharging can harm your battery and reduce its lifespan. To prevent this, use a charger with overcharge protection, which automatically shuts off once the battery is fully charged.
Charging a lead acid battery at high temperatures can cause serious damage to the battery and even lead to explosions. When a battery is overcharged, it may experience: Reduced Battery Life: Exaggerated use increases internal resistance, reducing the number of cycles performed.
Yes, you can leave a lead-acid battery charging overnight. However, it is important to ensure that the charging equipment is suitable for the battery and that it is being charged at the correct voltage and current levels. Overcharging a lead-acid battery can cause damage and reduce its lifespan. How long should you charge a lead acid battery?
If used and maintained properly, lead acid batteries can provide long-term stability. However, some improper operation of the battery will affect the performance of the lead acid battery, or even lead to premature obsolescence of the battery. In our daily life, a very common mistake is to overcharge the battery.
A sealed lead-acid battery can be used (discharged) as it can be stored in any position and is usually certified for air transport. With the electrolyte stabilized, there is generally no possibility for spillage of electrolyte in this type of battery as there is in a wet battery.
Yes, a lead-acid battery can explode if it is overcharged, damaged, or exposed to high temperatures. When a lead-acid battery is overcharged, the electrolyte solution can boil, releasing hydrogen gas. If the gas is not properly vented, it can build up and ignite, causing an explosion. What is the optimal charging voltage for a lead acid battery?
To charge a lead-acid battery, first connect the charger to the battery system before powering up or plugging in the charger. Another caution for discharged batteries: The electrolyte at this point is mostly water and will freeze at a higher temperature (15 to 20 degrees F.) than a fully charged battery.
A valve regulated lead‐acid (VRLA) battery, commonly known as a sealed lead-acid (SLA) battery, is a type of characterized by a limited amount of electrolyte ("starved" electrolyte) absorbed in a plate separator or formed into a gel, proportioning of the negative and positive plates so that oxygen recombination is facilitated within the, and the presence of a relief.
The valve-regulated lead–acid (VRLA) battery is designed to operate by means of an internal oxygen cycle (or oxygen-recombination cycle), where oxygen is evolved during the latter stages of charging and during overcharging of the positive electrode.
Valve-regulated lead–acid (VRLA) batteries are also referred to as 'recombinant' batteries. Unlike flooded batteries, which lose water as a result of oxygen and hydrogen evolution at the positive and negative electrodes respectively during charging, in VRLAs, oxygen will recombine with the hydrogen to reform water .
Charge profiles for new 6 V 100 Ah valve-regulated lead–acid (VRLA) batteries at different charge voltages and temperatures. Reproduced from Culpin B (2004) Thermal runaway in valve-regulated lead-acid cells and the effect of separator structure. Journal of Power Sources 133: 79–86; Figure 1. Figure 9.
general rule of thumb for a vented lead-acid battery is that the battery life is halved for every 15°F (8.3°C) above 77°F (25°C). Thus, a battery rated for 5 years of operation under ideal conditions at 77°F (25°C) might only last 2.5 years at 95°F (35°C).
To ensure maximum life, a lead–acid battery should be fully recharged as soon after a discharge cycle as possible to prevent sulfation, and kept at a full charge level by a float source when stored or idle (or stored dry new from the factory, an uncommon practice today).
Lead-acid batteries were used in e-bikes for the first time in the early 1900s [103–105]. The first generation of lead-acid batteries had a liquid acid electrolyte, which required more maintenance, and involved chemical leak hazards when the battery or bicycle fell .
Lead batteries are by far the safest technology when it comes to the risks of overcharging, exposure to heat, mechanical damage and short-circuiting.
Also, in the unfortunate event of a car accident, no acid will spill out if the battery is cracked or punctured. The lead battery chemistry is abuse tolerant, versatile, and a safe and reliable battery technology. Lead batteries have a long history of battery safety as the most reliable, safe and trusted technology for energy storage.
Lead acid batteries can be hazardous. They deliver a strong electric charge and release flammable hydrogen and oxygen gases when charged. This increases the risk of explosions. Safe handling and following precautions are crucial to prevent injuries and ensure safety when working with these batteries.
Health and Safety Standards: Health and safety standards mandate workplace safety protocols for those handling lead acid batteries. These standards are intended to minimize exposure to toxic lead and sulfuric acid. Employers must provide appropriate personal protective equipment (PPE) and training for workers.
The hazards associated with lead-acid batteries include chemical exposure, risks of explosion, environmental pollution, and health impacts. Understanding these hazards is essential for safe handling and management of lead-acid batteries. Chemical exposure occurs when handling lead-acid batteries improperly.
Lead-acid batteries release hydrogen gas during the charging process, which is highly flammable. The National Fire Protection Association (NFPA) suggests charging batteries in well-ventilated areas to prevent gas buildup and reduce fire risk. Additionally, careful storage and handling protocols must be established to mitigate these hazards.
Furthermore, the NFPA reports that (based on limited information) flooded lead-acid batteries are less prone to thermal runaways than valve-regulated lead-acid batteries (VRLA). That's because the liquid solution in flooded batteries can inhibit fire better than the materials inside VRLA batteries can. What Causes a Lead-Acid Battery to Explode?
The outdoor power supply is an outdoor multifunctional power supply with a built-in lithium-ion battery and its own electric energy storage, also known as a portable AC or DC power supply.
A portable power supply is a large-capacity power supply that can store electric energy in portable power stations. These portable power stations are ideal for use inside or outside your home during outdoor activities for a consistent energy supply. A portable power station has different outputs and can be charged in multiple ways.
A solar-powered portable power supply offers solar power solutions to homes. These are also used during blackouts, off-grid living, and outdoor adventures, ensuring flexibility through expanding the system with additional batteries. Portable power stations like the Jackery Portable Power Stations have developed portability.
If you use the portable power station for various scenarios, you can choose AC ports for electrical equipment, Type-C for charging smartphones, and DC carport for automotive equipment. Lead-acid and lithium-ion batteries are primarily used in portable power stations. Weight, capacity, and lifespan should be considered when choosing a battery type.
Because of their portability and convenience, portable energy storage power supplies are becoming popular. But there are some pros and cons of a portable power supply that you must be aware of: Portability: Portability is one of the most significant advantages of portable power stations.
Here are some tips for keeping the portable power supply: Regularly charge the battery: To keep your portable power station ready to use, make sure to charge the battery regularly. Even if you are not using it, you should charge the battery as this will extend the battery life and maintain its health. Store the battery in a cool place.
However, if you need to power a refrigerator, a television, and several other appliances, you may need a portable power station with thousands of watts of power. The number and types of outlets and ports on a portable power station will determine how many and what types of devices you can power.
There are four main benefits to having a residential or business battery system: increased reliability, addressing peak demand issues, grid stabilization and climate change.
High-power, high-capacity batteries will enhance opportunities for large-scale deployment of both distributed and centralized grid storage. Advancements in this technology will shape the future of energy storage.
A battery energy storage system (BESS) is an electrochemical device that charges (or collects energy) from the grid or a power plant and then discharges that energy at a later time to provide electricity or other grid services when needed.
Batteries and other energy storage technologies with bidirectional electrical energy storage capability to both supply and absorb electrical power can provide flexibility by helping to balance electrical supply and demand. Report Scope and Approach
IEC TC 120 has recently published a new standard which looks at how battery-based energy storage systems can use recycled batteries. IEC 62933‑4‑4, aims to “review the possible impacts to the environment resulting from reused batteries and to define the appropriate requirements”.
High-power, high-capacity batteries can lead to various co-benefits in infrastructure, including both storage and non-storage options. These benefits include energy savings, grid support services, and improved local air quality. (42,43)
The time for rapid growth in industrial-scale energy storage is at hand, as countries around the world switch to renewable energies, which are gradually replacing fossil fuels. Batteries are one of the options.
An automotive battery is a battery of any size or weight used for one or more of the following purposes: 1. starter or ignition power in a road vehicle engine 2. lighting power in a road vehicle A battery pack is a set of batteries connected or encapsulated within an outer casing which is: 1. formed and intended for use as a single, complete unit 2. not intended to be split up or. An industrial battery or battery pack is of any size or weight, with one or more of the following characteristics: 1. designed exclusively for industrial or. A portable battery or battery pack is a battery which meets all the following criteria: 1. sealed 2. weighs 4kg or below 3. not an automotive or. The 2008 and the 2009 regulations do not define a sealed battery. Defra and the regulators have adopted the International Electrotechnical.
[PDF Version]Batteries are classified as hazardous materials because they contain toxic substances like mercury, lead, cadmium, and lithium. Their classification varies based on chemical composition and toxicity, with common categories including lithium-ion and lead-acid batteries.
These fall under a different class of hazardous materials than their typical lead-acid automotive battery. So to answer what hazard class are automotive batteries, the answer is actually two different classes. These are class 8 and class 9 depending on the battery type. Is a Car Battery a Hazardous Material? Yes.
Automotive batteries are regulated as a class 8 hazardous material. Class 8 covers corrosive materials, such as the sulfuric acid inside of a typical automotive battery. These batteries also contain lead, which is a dangerous chemical substance, but sulfuric acid is what gives them a class 8 designation.
Within the lithium-ion battery dangerous goods classification, each different form of lithium-ion battery is assigned a UN number and proper shipping name. This indicates the nature of the goods being transported and helps govern materials under UN regulations and transport bodies set out above.
Yes. A typical car battery is a lead-acid battery, and the lead and acid are considered hazardous. Automotive Batteries Are An Example Of Which Hazardous Class? Because of the acid in a typical automotive battery, it would be an example of a class 8 hazardous material. Class 8 hazardous materials are defined as corrosive materials or substances.
Their classification helps us manage risks and guarantee safety. Industrial batteries are generally classified as Class 8 (corrosives) or Class 9 (miscellaneous hazardous materials) under the U.S. Department of Transportation (DOT). Class 8 includes batteries such as lead-acid, which can leak corrosive acid.
Lithium-ion and solid-state batteries are very much alike. Both types use lithium to produce electrical energy and they have an anode (the battery's negative terminal), a cathode (the battery's positive terminal), and an electrolyte, which helps transfer ions from the cathode to the anode and vice versa. They primarily differ in. Lithium-ion batteries are unfortunately flammable and this has mostly to do with their liquid electrolytes, which are volatile and unstable when exposed to high temperatures. In contrast,. Sodium-ion batteries come up a bit short here. Sodium ions are larger and denser than lithium ions, which means that we need a whole more lot of the former to store and produce the. Sodium's abundance naturally makes it a less expensive option. It also costs less to extract and purify. On top of that, sodium-ion cells can be made with ample metals such as iron and. Here we have the battle of the elements: lithium vs sodium. Lithium is a relatively rare element on Earth and its increasing demand doesn't come.
[PDF Version]They aren't all alike, and manufacturers use a range of different kinds of batteries. So we've decided to select and rank the three most prominent (or promising) battery types: lithium, solid-state, and sodium-ion batteries. We'll compare the batteries using four criteria: safety, energy density and charging time, sustainability, and price.
2024's advancements in battery safety reflect the industry's growing concern for safety as energy storage becomes more ubiquitous. As sectors like renewable energy and electric mobility scale, these safer battery technologies could shape future standards and pave the way for efficient and reliable energy storage.
The most costly option seems to be solid-state batteries, because solid electrolytes are more expensive to produce. Specifically, solid-state batteries are projected to cost $80-90/ kWh by 2030, while the price of lithium batteries is expected to reach $60/kWh by the same time. Winner: Sodium-ion batteries And the winner is Sodium-ion batteries!
Three main types of batteries dominate today's EV market: Lithium Iron Phosphate (LFP), Nickel Manganese Cobalt (NMC), and Nickel Cobalt Aluminum (NCA) batteries. According to the IEA's 2024 report, LFP and NMC batteries together account for over 90% of the global EV battery market.
If you are wondering what the safest lithium battery chemistry as of today LTO formally known as Lithium Titanate Oxide takes the safety crown. This chemistry is the safest due to its extremely stable chemical compositions and tolerance to harsh conditions.
In 2024, research focused on battery safety. Image used courtesy of Adobe Stock Lithium-ion batteries are efficient but prone to fire risks due to their flammable electrolytes, typically composed of lithium salts dissolved in organic solvents.
Lead-acid batteries are increasingly being deployed for grid-scale energy storage applications to support renewable energy integration, enhance grid stability, and provide backup power during peak.
Additionally, they power essential electrical components in vehicles, such as lights, infotainment systems, and air conditioning when the engine is off. Renewable Energy Storage (Solar and Wind Systems): In renewable energy, lead-acid batteries are pivotal for storing energy generated from solar panels and wind turbines.
Lead–acid batteries were used to supply the filament (heater) voltage, with 2 V common in early vacuum tube (valve) radio receivers. Portable batteries for miners' cap headlamps typically have two or three cells. Lead–acid batteries designed for starting automotive engines are not designed for deep discharge.
Now, compared to the latest battery tech, lead-acid batteries have a lower energy density compared to lithium-ion batteries, but they compensate with their robustness and cost-effectiveness for large-scale energy storage. This is key in industrial applications, where machinery demands a steady and reliable energy source.
Lead batteries cover a range of different types of battery which may be flooded and require maintenance watering or valve-regulated batteries and only require inspection.
Lead–acid batteries have been used for energy storage in utility applications for many years but it has only been in recent years that the demand for battery energy storage has increased.
When it comes to solar power, lead-acid batteries have carved a niche in photovoltaic (PV) systems. Their integration in these systems is pivotal for harnessing and storing solar energy. As sunlight is intermittent, lead-acid batteries ensure that the energy captured during sunny periods is not wasted but stored for later use.
Battery swapping or battery switching is an technology that allows to quickly exchange a discharged for a fully charged one, rather than to recharge the vehicle via a. Battery swapping is common in electric applications. As of 2021, Taiwanese manufacturer operates the larg.
Battery swapping or battery switching is an electric vehicle technology that allows battery electric vehicles to quickly exchange a discharged battery pack for a fully charged one, rather than to recharge the vehicle via a charging station. Battery swapping is common in electric forklift applications.
There are currently over 900 operational battery swapping stations across China and one in Norway, with the company planning on expanding across the rest of Norway and Europe. To date, those stations have carried out over seven million swaps, with thousands more taking place every hour.
The swapping station can also cater for different battery capacities, from 75kWh to 150kWh, although there's still a long way to go before these stations will be accessible for all BEV (battery electric vehicle) owners. Chinese automotive company Nio pioneered battery swapping technology in China, installing 700 stations by the end of 2021.
A Nio battery swap station at a carpark in Beijing. Battery swapping or battery switching is an electric vehicle technology that allows battery electric vehicles to quickly exchange a discharged battery pack for a fully charged one, rather than to recharge the vehicle via a charging station.
All of the Power Swap Stations feature a number of conventional EV chargers, which are available to all EV drivers and can take energy from the stored batteries at times of peak demand. In China, the battery swap sites are open to Nio drivers who own their batteries outright or who lease them.
Electric vehicle owners may soon be able to swap their car batteries in as little as five minutes with new groundbreaking technology set to hit the UK soon. Nio, a premium Chinese car manufacturer, has launched the third generation of its Power Swap Stations, which allow motorists to replace their batteries in under five minutes.
The most notable difference between lithium iron phosphate and lead acid is the fact that the lithium battery capacity is independent of the discharge rate. The figure below compares the actual capacity as a percentage of the rated capacity of the battery versus the discharge rate as expressed by C (C equals the. Lithium delivers the same amount of power throughout the entire discharge cycle, whereas an SLA's power delivery starts out strong, but. Charging SLA batteries is notoriously slow. In most cyclic applications, you need to have extra SLA batteries available so you can still use your application while the other battery is charging. Cold temperatures can cause significant capacity reduction for all battery chemistries. Knowing this, there are two things to consider when. Lithium's performance is far superior than SLA in high temperature applications. In fact, lithium at 55°C still has twice the cycle life as SLA does at.
[PDF Version]If you need a battery backup system, both lead acid and lithium-ion batteries can be effective options. However, it's usually the right decision to install a lithium-ion battery given the many advantages of the technology - longer lifetime, higher efficiencies, and higher energy density.
Electrolyte: Dilute sulfuric acid (H2SO4). While lithium batteries are more energy-dense and efficient, lead acid batteries have been in use for over a century and are still widely used in various applications. II. Energy Density
Here we look at the performance differences between lithium and lead acid batteries The most notable difference between lithium iron phosphate and lead acid is the fact that the lithium battery capacity is independent of the discharge rate.
Lead acid batteries comprise lead plates immersed in an electrolyte sulfuric acid solution. The battery consists of multiple cells containing positive and negative plates. Lead and lead dioxide compose these plates, reacting with the electrolyte to generate electrical energy. Advantages:
Hence, comparing the cost of lithium-ion batteries vs lead acid, the lead-acid batteries may seem cost-effective initially, considering the lifespan, lithium-ion batteries may prove to be more economical in the long run, despite their higher upfront and installation costs. 8. Cycle Life
Environmental Concerns: Lead acid batteries contain lead and sulfuric acid, both of which are hazardous materials. Improper disposal can lead to soil and water contamination. Recycling Challenges: While lead acid batteries are recyclable, the recycling process is often complex and costly.
LFPs have a longer lifespan than any other battery. A deep-cycle lead acid battery may go through 100-200 cyclesbefore its performance declines and drops to 70–80% capacity. On average, lead-acid batteries have a cycle count of around 500, while lithium-ion batteries may last 1,000 cycles. In comparison, the LFP. LiFePO4 is a safer technology when compared to Li-ion and other battery types. Specifically, they don't have the issues of toxic fumes and off-gassing associated with Lithium. You can charge LiFePO4 batteries much more quickly compared to other battery types, typically within 1-2 hours using AC power and 3-6 hours using solar panels. The actual charging time depends on several factors, including. LFPs have a higher energy density compared to some other battery types. Energy density refers to the amount of energy a battery can store per unit of volume or weight. LiFePO4 batteries have an energy density of. LiFePO4 batteries have an operating temperature range between -4°F and 140°F (-20°C to 60°C). The temperature range allows them to perform well even in climates or conditions with extreme cold or heat. However, keeping.
[PDF Version]While Lithium Iron Phosphate (LFP) batteries offer a range of advantages such as high energy density, long lifespan, and superior safety features, they also come with certain drawbacks like lower specific power and higher initial costs.
Lithium Iron Phosphate (LFP) batteries, also known as LiFePO4 batteries, are a type of rechargeable lithium-ion battery that uses lithium iron phosphate as the cathode material. Compared to other lithium-ion chemistries, LFP batteries are renowned for their stable performance, high energy density, and enhanced safety features.
With a composition that combines lithium iron phosphate as the cathode material, these batteries offer a compelling blend of performance, safety, and longevity that make them increasingly attractive for various industries.
Lithium Iron Phosphate (LFP) batteries have emerged as a promising energy storage solution, offering high energy density, long lifespan, and enhanced safety features. The high energy density of LFP batteries makes them ideal for applications like electric vehicles and renewable energy storage, contributing to a more sustainable future.
Lithium iron phosphate batteries have the ability to deep cycle but at the same time maintain stable performance. A deep-cycle is a battery that's designed to produce steady power output over an extended period of time, discharging the battery significantly. At that point, the battery must be recharged to complete the cycle.
Lithium Iron Phosphate (LiFePO4) batteries are a promising technology with a robust chemical structure, resulting in high safety standards and long cycle life. Their cathodes and anodes work in harmony to facilitate the movement of lithium ions and electrons, allowing for efficient charge and discharge cycles.
PV systems are most commonly in the grid-connected configuration because it is easier to design and typically less expensive compared to off-grid PV systems, which rely on batteries. Grid-connected PV systems allow homeowners to consume less power from the grid and supply unused or excess power back to the. Off-grid (stand-alone) PV systems use arrays of solar panels to charge banks of rechargeable batteries during the day for use at night when energy. Solar panels used in PV systems are assemblies of solar cells, typically composed of silicon and commonly mounted in a rigid flat. A PV combiner box receives the output of several solar panel strings and consolidates this output into one main power feed that connects to an inverter. PV combiner boxes are. When solar arrays are installed on a property, they must be mounted at an angle to best receive sunlight. Typical solar array mounts include roof, freestanding, and directional tracking mounts (see Figure 4).
[PDF Version]
Yes, batteries can be stored stacked, but it is crucial to follow specific guidelines to ensure safety and performance. Proper stacking prevents damage and maintains battery integrity.
Lead acid batteries contain toxic substances; therefore, recycling is essential to recover lead and other materials. The Rechargeable Battery Recycling Corporation notes that over 95% of lead from recycled batteries can be reused, significantly reducing the need for new lead extraction. 5. Health and Safety Standards:
EPA guidelines dictate how lead acid batteries must be managed during all phases. The Environmental Protection Agency (EPA) considers lead acid batteries hazardous waste when improperly disposed of. All lead acid batteries should be stored, treated, and disposed of in accordance with the Resource Conservation and Recovery Act (RCRA).
Nowadays modern plastics are impervious to acid so there is no risk of this happening. Myth: It is okay to store lead acid batteries anywhere inside or outside. Fact: It is good to store lead acid batteries in cool places because the self-discharge is lower but be careful not to freeze the battery.
Proper training and awareness can prevent accidents and promote a safer environment. What Are the Hazards Associated with Lead Acid Batteries? The hazards associated with lead-acid batteries include chemical exposure, risks of explosion, environmental pollution, and health impacts.
However, most chargers sold today are “smart” chargers and will shut off after the battery is fully charged. Myth: Any charger should work perfectly okay with any type of lead acid battery. Fact: There are many different technologies used in lead acid batteries.
Myth: The worst thing you can do is overcharge a lead acid battery. Fact: The worst thing you can do is under-charge a lead acid battery. Regularly under-charging a battery will result in sulfation with permanent loss of capacity and plate corrosion rates upwards of 25x normal.
In the United Kingdom the Batteries and Accumulators (Placing on the Market) Regulations 2008 are the underpinning legislation: 1. making it compulsory to collect and recycle batteries and accumulators 2. preventing batteries and accumulators from being incinerated or dumped in landfills 3. restricting the substances. The regulations cover all types of batteries, regardless of their shape, volume, weight, material composition or use; and all appliances into which a battery is or may be incorporated. There are some exemptions. If you design or manufacture any type of battery or accumulator for the UKmarket, including batteries that are incorporated in appliances, they: 1. cannot contain more than the agreed levels of. The Office for Product Safety and Standards has been appointed by Defra to enforce the regulations in the United Kingdom.
[PDF Version]The Regulations set out requirements for waste battery collection, treatment, recycling and disposal for all battery types including arrangements by which the UK intends to meet portable battery collection targets of 25% by 2012 and 45% by 2016.
The specific obligations in relation to waste batteries depend on their type, but all require registration with the appropriate environmental regulator via the National Packaging Waste Database.
Who is affected? The main groups who will be affected by the regulations are people who place batteries or equipment containing batteries on the market in the UK. The requirements may differ depending upon whether the batteries in question are automotive, industrial or portable.
Dependent on the legislation item being viewed this may include: These Regulations partially implement Directive 2006/66/EC of the European Parliament and of the Council on batteries and accumulators and waste batteries and accumulators and repealing Council Directive 91/157/EEC (OJ No. L266, 26.9.2006, p.1) (“the Directive”).
Your business must comply with the batteries regulations if it manufactures batteries or equipment containing batteries, or is involved in the separate collection, treatment, recycling, or export of waste batteries for recycling.
The regulations cover all types of batteries, regardless of their shape, volume, weight, material composition or use; and all appliances into which a battery is or may be incorporated. There are some exemptions including batteries used in:
If the battery voltage goes below 11 volts, the battery should be charged immediately. Leaving it for a week or more before recharging will seriously impair life and storage capacity.
Lead–acid batteries were used to supply the filament (heater) voltage, with 2 V common in early vacuum tube (valve) radio receivers. Portable batteries for miners' cap headlamps typically have two or three cells. Lead–acid batteries designed for starting automotive engines are not designed for deep discharge.
The lead–acid battery is a type of rechargeable battery first invented in 1859 by French physicist Gaston Planté. It is the first type of rechargeable battery ever created. Compared to modern rechargeable batteries, lead–acid batteries have relatively low energy density. Despite this, they are able to supply high surge currents.
Sulfation prevention remains the best course of action, by periodically fully charging the lead–acid batteries. A typical lead–acid battery contains a mixture with varying concentrations of water and acid.
@transistor ofc is an Internet-ism meaning "of course". A 12V lead-acid battery will not be damaged by overcharge if the voltage is kept low enough to avoid electrolysis, and the charging current is kept below 0.2C (5 times less than the Ah capacity). Some types of lead-acid battery can handle higher voltage that others.
Under Voltage batteries destroy the battery by causing sulfation in Lead Acid Batteries, or Dendrites in Lithium. Both are very destructive. People who say that the battery can handle it are really saying that their battery is a better quality battery than usual.
Flooded lead-acid batteries can be charged to 14.4V or higher, so long as they are kept topped up with deionized water (but this is not recommended because hydrogen/oxygen gas is explosive!). However if your AC adapter puts out exactly 12VDC then the battery won't be charged either, so you will damage it by undercharge.