Browse technical resources about commercial solar, energy storage, EMS/BMS/PCS, microgrids, and peak arbitrage.
Formulas for Calculating Battery Charge TimeBasic Formula Charge Time = Battery Capacity (Ah) / Charging Current (A) This formula is a straightforward way to estimate charge time. Battery Charge Time Calculator. Advanced Considerations for Rechargeable Batteries. Real-World ExamplesA Smartphone.
The Battery Charge Calculator is designed to estimate the time required to fully charge a battery based on its capacity, the charging current, and the efficiency of the charging process. This tool is invaluable for users who rely on battery-operated devices, whether for personal use, industrial applications, or renewable energy systems.
Now you have your battery capacity and charging current in 'matching' units. Finally, you divide battery capacity by charging current to get charge time. In this example, your estimated battery charging time is 1.5 hours. Formula: charge time = battery capacity ÷ (charge current × charge efficiency) Accuracy: Medium Complexity: Medium
Charger Current (A): The charger's output current is typically measured in Amps (A) or milliamps (mA). To consider the current charge level, we multiply the battery capacity by the uncharged percentage. Effective Capacity (Ah) = Battery Capacity (Ah) × (1−Charge Level/100) Let's say you have:
The time required to charge a battery pack based on its capacity (Wh, kWh, Ah, or mAh) and the charging current (A or mA). Charging Current The current supplied by the charger to charge the battery pack. Current State of Charge (SoC) The current charge level of the battery pack as a percentage.
Battery charging time is the amount of time it takes to fully charge a battery from its current charge level to 100%. This depends on several factors such as the battery's capacity, the charger's voltage output, and the battery charge level. The basic formula used in our calculator is: Charging Time = Battery Capacity (Ah) / Charger Current (A)
2000mAh = 2Ah Consider Charge Level: The battery is already at 50%, so only 50% of its capacity needs to be charged: Effective Capacity = 2Ah × (1−0.50) = 1Ah Calculate Charging Time: Now, divide the effective capacity by the charger's current: Charging Time = 1Ah / 1A = 1 hour
This study addresses the optimization of heat dissipation performance in energy storage battery cabinets by employing a combined liquid-cooled plate and tube heat exchange method for battery pack cooling, thereby enhancing operational safety and efficiency.
The formula for calculating battery storage capacity is relatively straightforward and involves multiplying the battery voltage by the amp-hour (Ah) rating of the battery.
The battery energy calculator allows you to calculate the battery energy of a single cell or a battery pack. You need to enter the battery cell capacity, voltage, number of cells and choose the desired unit of measurement. The default unit of measurement for energy is Joule.
The battery pack capacity C bp is calculated as the product between the number of strings N sb [-] and the capacity of the battery cell C bc . The total number of cells of the battery pack N cb [-] is calculated as the product between the number of strings N sb [-] and the number of cells in a string N cs [-].
The required battery pack total energy E bp is calculated as the product between the average energy consumption E avg [Wh/km] and vehicle range D v . For this example we'll design the high voltage battery pack for a vehicle range of 250 km. The following calculations are going to be performed for each cell type.
This battery pack calculator is particularly suited for those who build or repair devices that run on lithium-ion batteries, including DIY and electronics enthusiasts. It has a library of some of the most popular battery cell types, but you can also change the parameters to suit any type of battery.
Fill in the number of cells in series and parallel, the capacity of a single cell in mAh, and the voltage of a single cell in volts (default is 3.7V). Press the “Calculate” button to get the total voltage, capacity, and energy of the battery pack. This calculator assumes that all cells have identical capacity and voltage.
The total number of cells of the battery pack N cb [-] is calculated as the product between the number of strings N sb [-] and the number of cells in a string N cs [-]. The size and mass of the high voltage battery are very important parameter to consider when designing a battery electric vehicle (BEV).
Safe temperature limits for charging car batteries generally range from 32°F (0°C) to 113°F (45°C). Beyond this range, the risk of damage increases.
Batteries can be discharged over a large temperature range, but the charge temperature is limited. For best results, charge between 10°C and 30°C (50°F and 86°F). Lower the charge current when cold. Nickel Based: Fast charging of most batteries is limited to 5°C to 45°C (41°F to 113°F).
At extremely low temperatures, such as -40°C (-40°F), the charging voltage per cell can rise to approximately 2.74 volts, equating to 16.4 volts for a typical lead-acid battery. Conversely, at higher temperatures around 50°C (122°F), the charging voltage drops to about 2.3 volts per cell, or 13.8 volts in total.
Charging and discharging are key processes that can be deeply affected by temperature. Charging: Charging a battery at an improper temperature (either too hot or too cold) can be harmful. Charging in heat can result in overheating and decreased battery life, while cold charging can lead to incomplete charging and internal damage.
Charging a battery to its full capacity in cold conditions requires a higher voltage. It's crucial that the charging voltage adapts to the surrounding temperature of the battery to not only guarantee a complete charge, but also to prevent the risk of overcharging when the temperatures are high.
If the float voltage is set to 2.30V/cell at 25°C (77°F), the voltage should read 2.27V/cell at 35°C (95°F). Going colder, the voltage should be 2.33V/cell at 15°C (59°F). These 10°C adjustments represent 30mV change. Table 3 indicates the optimal peak voltage at various temperatures when charging lead acid batteries.
Slower Charging: Cold temperatures also affect the charging rate of batteries. Charging a battery when it's too cold can cause it to charge more slowly or fail to charge altogether. In extreme cases, charging in cold conditions can cause the battery to be damaged permanently, resulting in reduced performance over time.
Lead batteries are by far the safest technology when it comes to the risks of overcharging, exposure to heat, mechanical damage and short-circuiting.
Also, in the unfortunate event of a car accident, no acid will spill out if the battery is cracked or punctured. The lead battery chemistry is abuse tolerant, versatile, and a safe and reliable battery technology. Lead batteries have a long history of battery safety as the most reliable, safe and trusted technology for energy storage.
Lead acid batteries can be hazardous. They deliver a strong electric charge and release flammable hydrogen and oxygen gases when charged. This increases the risk of explosions. Safe handling and following precautions are crucial to prevent injuries and ensure safety when working with these batteries.
Health and Safety Standards: Health and safety standards mandate workplace safety protocols for those handling lead acid batteries. These standards are intended to minimize exposure to toxic lead and sulfuric acid. Employers must provide appropriate personal protective equipment (PPE) and training for workers.
The hazards associated with lead-acid batteries include chemical exposure, risks of explosion, environmental pollution, and health impacts. Understanding these hazards is essential for safe handling and management of lead-acid batteries. Chemical exposure occurs when handling lead-acid batteries improperly.
Lead-acid batteries release hydrogen gas during the charging process, which is highly flammable. The National Fire Protection Association (NFPA) suggests charging batteries in well-ventilated areas to prevent gas buildup and reduce fire risk. Additionally, careful storage and handling protocols must be established to mitigate these hazards.
Furthermore, the NFPA reports that (based on limited information) flooded lead-acid batteries are less prone to thermal runaways than valve-regulated lead-acid batteries (VRLA). That's because the liquid solution in flooded batteries can inhibit fire better than the materials inside VRLA batteries can. What Causes a Lead-Acid Battery to Explode?
Blade Batteries boast a higher energy density compared to traditional lithium-ion batteries, allowing for greater energy storage in a smaller footprint.
BYD's blade battery 2.0 will have an energy density of up to 210 Wh/kg and support 16C peak discharge. BYD will offer a short blade format for its second-gen lithium iron phosphate battery (LFP) with 160 Wh/kg energy density, a maximum discharge rate of 16C, and an 8C charge rate.
The new unit will have an energy density of up to 210 Wh/kg with 16C peak discharge. There will reportedly be two versions, one offering a lower energy density. BYD's higher energy density (210 Wh/kg) Blade battery will support an 8C discharge rate and 3C charge rate.
The blade battery currently has about 150 Wh/kg energy density. The lower energy density version, offering higher charge and discharge rates due to reduced resistance, will be priced similarly to the current generation blade battery or slightly higher.
Blade battery 2.0 will have an energy density of 210 Wh/kg and support up to 16C discharge.
The new Blade batteries will feature higher energy density and faster charging rates. According to the latest, they will also get a price reduction. A source close to the matter told CarNewsChina that BYD aims for a 15% cost reduction for the new Blade EV battery. The new unit will have an energy density of up to 210 Wh/kg with 16C peak discharge.
In the longer blade format, the battery will have an energy density of up to 210 Wh/kg, a charge rate of 3C and a discharge rate of 8C. The Blade battery, which was first introduced in 2020, is an in-house development by BYD. The name refers to the unusual format: the cells are very long and therefore resemble a sword blade.
BS EN50171 is a European standard that sets out requirements for central battery systems that are designed to provide power to emergency lighting and other critical safety applications.
This standard ensures that emergency lighting is properly installed, maintained, and functional during power failures or other emergencies. The British Standard applies to most premises, including workplaces, public buildings, residential buildings, and communal areas in multiple-occupancy buildings.
Under UK fire safety legislation your business has a legal obligation to ensure systems are maintained correctly. Emergency lighting is a broad term for systems that provide an alternative light source when the power supply to normal lighting fails. British Standard BS EN 1838 identifies different classes of emergency lighting system:
Emergency lighting systems should be designed, installed, commissioned and maintained to the recommendations of British Standard BS 5266-1. Choosing an NSI approved company ensures your emergency lighting system will meet this standard.
7.9.2.2 New emergency power systems for emergency lighting shall be at least Type 10, Class 1.5, Level 1, in accordance with NFPA 110, Standard for Emergency and Standby Power Systems. (3) Manual act (s), including accidental opening of a switch controlling normal lighting facilities.
7.9.2.1.3 The maximum-to-minimum illumination shall not exceed a ratio of 40 to 1. 7.9.2.2 New emergency power systems for emergency lighting shall be at least Type 10, Class 1.5, Level 1, in accordance with NFPA 110, Standard for Emergency and Standby Power Systems.
Emergency lighting regulations are designed to ensure that buildings have adequate lighting systems in place to provide safe evacuation routes during emergencies, such as power outages, fires, or other incidents that disrupt normal lighting.
Many smart devices have built-in battery packs, with modern laptops packing enough cells to last a whole day. However, typical desktop computers, routers, and similar devices still need to be plugged into a power source all the time to work. That's where an uninterruptible power supply (UPS) comes in. Its main function is to. Our pick for the best UPS overall goes to the APC BR1500G Backup Battery. At 1500VA/865W, it can power most devices, including computers, external hard drives, and wireless routers, from. If you need a UPS and don't want to spend a lot, the APC UPS BE425M Battery Backupis for you. Its 425VA/225W power won't keep your desktop. The Amazon Basics Standby UPSis great for those who want a UPS compact enough to fit in a small space but packs decent power for their. Most laptops have a long enough battery life to last anywhere from a few hours to an entire day. So, if you don't have a larger, more power-hungry desktop, you only need a smaller UPS.
[PDF Version]
The lithium iron phosphate battery (LiFePO 4 battery) or LFP battery (lithium ferrophosphate) is a type of using (LiFePO 4) as the material, and a with a metallic backing as the. Because of their low cost, high safety, low toxicity, long cycle life and other factors, LFP batteries are finding a number o.
Cycling Stability of Lithium Iron Phosphate Batteries. 88.7 % after 1200 cycles at 1C. Negligible degradation after 250 cycles at a 1C. 96.30 % after 1500 cycles at 2C. 80.4 % after 1000cycles at 1.0C, and 90.2 after 550cycles at 1.0C. 97.2 % after 700 cycles. 98.3 % after 500 cycles at 1C. 153.2 mAh/g after 500 cycles at 0.5C.
The objective of this research is to calculate the varying entropic coefficient values of the lithium-iron phosphate battery. A 14Ah lithium ion pouch cell, with a dimension of 220 mm × 130 mm × 7 mm, was studied in both charge and discharge. The SOC levels range from full charge to full discharge in 5% increments.
To investigate the cycle life capabilities of lithium iron phosphate based battery cells during fast charging, cycle life tests have been carried out at different constant charge current rates. The experimental analysis indicates that the cycle life of the battery degrades the more the charge current rate increases.
According to the Shepherd model, the dynamic error of the discharge parameters of the lithium iron phosphate battery is analyzed. The parameters are the initial voltage Es, the battery capacity Q, the discharge platform slope K, the ohmic resistance N, the depth of discharge (DOD), and the exponential coefficients A and B.
The lithium iron phosphate (LFP) cell chemistry is gaining wide acceptance in battery electric vehicle (BEV) applications. Its inherent ability to tolerate abusive conditions and resist thermal runaway is especially attractive to battery pack designers. Battery manufacturers have responded by offering high capacity cells in a pouch format.
Since its first introduction by Goodenough and co-workers, lithium iron phosphate (LiFePO 4, LFP) became one of the most relevant cathode materials for Li-ion batteries and is also a promising candidate for future all solid-state lithium metal batteries.
When handling lithium-ion batteries, safety precautions are a must:1. Cracks, dents, or leaks should be treated as warning signs. Avoid exposing batteries to heat or fire.
These pages are undergoing reviews and updates. A lithium battery fire in the hold of an aircraft is a significant safety risk. Domestic and international incidents relating to lithium batteries have often involved incorrectly packed, marked and labelled batteries, as well as mis-declared or undeclared consignments.
Whether manufacturing or using lithium-ion batteries, anticipating and designing out workplace hazards early in a process adoption or a process change is one of the best ways to prevent injuries and illnesses.
From electric vehicles to laptops to massive grid storage systems, the demand for batteries is growing. And so is the need to ship batteries safely and efficiently. But hold up! You can't just toss lithium batteries in a box and call it a day. Transporting batteries is a serious business.
The transport of lithium batteries on their own is forbidden in the hold of passenger aircraft. Continued reporting of incidents is vital to help monitor current and emerging risks. Report a dangerous goods accident or incident. UK Mandatory Occurrence Reporting (MOR).
While there is not a specific OSHA standard for lithium-ion batteries, many of the OSHA general industry standards may apply, as well as the General Duty Clause (Section 5(a)(1) of the Occupational Safety and Health Act of 1970). These include, but are not limited to the following standards:
Lithium batteries that are not transported in accordance with the applicable requirements present an increased likelihood of a fire in the cargo compartment, potentially resulting in a catastrophic incident.
The liquid inside a battery is called the electrolyte. It plays a crucial role in enabling the flow of electric charge between the battery's positive and negativeelectrodes. Without the electrolyte, batteries w. Batteries come in two main categories: primary batteries, which are disposable, and secondary batteries, which can be recharged. Let's take a look at both types: The type of liquid electrolyte used in a battery depends on the specific chemistry of the battery. Let's examine the electrolytes in some common battery types: The liquid inside a battery, known as the electrolyte, is a critical component that enables the flow of electric charge and facilitates redox reactions. Electrolytes vary depending on the battery type and chemistry, and th. What is the liquid inside a battery called? The liquid inside a battery is called the electrolyte. It facilitates the flow of ions between the battery's positive and negative electrodes, enabling the generation of electric current. A.
[PDF Version]Solid state batteries are primarily composed of solid electrolytes (like lithium phosphorus oxynitride), anodes (often lithium metal or graphite), and cathodes (lithium metal oxides such as lithium cobalt oxide and lithium iron phosphate). The choice of these materials affects the battery's energy output, safety, and overall performance.
Graphite is the most popular material used for the anode in lithium-ion batteries. On the other hand, cathodes are typically made of lithium cobalt oxide, lithium iron phosphate, or lithium manganese oxide. The chemistry of the cathode material directly correlates to the battery's chemistry.
The inside of a lithium battery contains multiple lithium-ion cells (wired in series and parallel), the wires connecting the cells, and a battery management system, also known as a BMS. The battery management system monitors the battery's health and temperature.
This common type of battery electrolyte is an inorganic compound, commonly referred to as caustic potash. The material is generally harmless as long as we do not ingest it, and it is an ingredient in most soft and liquid soaps. ELECTROLYTES IN LITHIUM-ION BATTERIES Lithium-ion batteries use liquid, gel, or dry polymer electrolytes.
We review common types of battery electrolytes, because different chemistries require different solutions. There are several generic types of electrolytes, which engineers tweak to suit particular applications. Broadly speaking: Electrolytes comprise soluble salts, acids, or other bases. These alternatives may be in liquid gel, or dry formats.
Solid state batteries utilize solid materials instead of liquid electrolytes, making them safer and more efficient. They consist of several key components, each contributing to their overall performance. Solid electrolytes allow ion movement while preventing electron flow. They offer high stability and operate at various temperatures.
The charge and discharge process of new energy batteries is an electrochemical reaction process, in which the chemical energy and electrical energy inside the battery are converted to each other.
Charging and Discharging Definition: Charging is the process of restoring a battery's energy by reversing the discharge reactions, while discharging is the release of stored energy through chemical reactions. Oxidation Reaction: Oxidation happens at the anode, where the material loses electrons.
The key to EVs is their power batteries, which undergo a complex yet crucial charging and discharging process. Understanding these processes is crucial to grasping how EVs efficiently store and use electrical energy. This article will explore the intricate workings of the charging and discharging processes that drive the electric revolution.
This article will explore the intricate workings of the charging and discharging processes that drive the electric revolution. Power Connection: To begin the charging process, the electric vehicle is linked to a power source, usually a charging pile or a charging station.
Discharge Process: During the discharge process, the battery's chemical reactions undergo a reversal. Lithium ions migrate from the negative electrode to the positive electrode, while electrons travel from the negative electrode to the positive electrode.
Finally, the battery charging and discharging process is optimized and analyzed to obtain better anti-aging and safety performance. By clarifying the degradation mechanism and proposing effective measures, it is of great benefit to the design and operation of battery management system. 1. Introduction
The discharge rate is determined by the vehicle's acceleration and power requirements, along with the battery's design. The charging and discharging processes are the vital components of power batteries in electric vehicles. They enable the storage and conversion of electrical energy, offering a sustainable power solution for the EV revolution.
Conversely, the drawbacks include large number of interconnections, higher integration and assembly cost, lower weight and volume efficiency, and lower reliability.
Excessive heat generated from a short-circuited cell will pose a fire hazard to the battery pack. One of the disadvantages of having a large number of parallel connections is that a thick connector must be used to carry high current flow into or out of the battery module.
Electrical unbalance of the cells in the battery pack may be caused by different cell SOC, current leakage, different internal resistances or capacity. Only manufacturers with tight quality control can provide high consistency products that require minor balancing efforts.
Uneven electrical current distribution in a parallel-connected lithium-ion battery pack can result in different degradation rates and overcurrent issues in the cells. Understanding the electrical current dynamics can enhance configuration design and battery management of parallel connections.
Currently, the limited capacity of electric vehicle batteries are perceived as a disadvantage to consumers. Moreover, the batteries are the most expensive part of an electric car. Battery companies are looking for ways to keep up with the demand for EV batteries while also staying competitive in this challenging landscape.
Distributed battery systems require a different control approach that are more complex than conventional single battery systems. In these scenarios, control structures consist of a Module Control Unit (MCU) and a Battery Control Unit (BCU) that has a master role. A master control unit is required for parallel packs.
Understanding the electrical current dynamics can enhance configuration design and battery management of parallel connections. This paper presents an experimental investigation of the current distribution for various discharge C-rates of both parallel-connected LiFePO 4 and Li (NiCoAl)O 2 cells.
The negative terminal is color-coded black and will be connected to the minus side of the battery. The negative wiring insulator will be colored black, and the negative terminal attaches directly to the negative side of the battery and to the metal chassis of the car. If you have ever wondered what the difference is between. Battery failure is common, but so too is assuming a flat battery means your battery is faulty. Misdiagnosing a battery can be an expensive mistake. Checking battery voltage as per the above. A car battery will have a fastener on each terminal and a third fastener; the battery hold down, and it secures the battery to the chassis of the car. Your symptoms could range from: 1. No power at all, anywhere 2. Ignition lights work, but the engine won't crank 3. Car cranks but won't start 4. You'll need a donor vehicle or a spare battery or alternatively, consider buying a jump pack. The little NOCO Boost pack is about the best I've seen, and I've been a mechanic for over twenty-five years. It's small enough to fit in a.
[PDF Version]The red positive on a car battery, often labeled with a positive or plus sign, is the positive terminal. The black negative on a car battery, labeled with a negative or minus sign, is the negative terminal. Attach the red cable to the positive terminal and attach the black cable to the negative terminal. 1.
You can identify the positive and negative terminals on a car battery by looking for color-coded markings and symbols. The positive terminal usually has a red cover or marking, while the negative terminal is typically marked with black or has a minus sign (-). Color coding: The positive terminal features a red color or cover.
You can recognize a negative terminal on a car battery by its color and symbol, as it is typically marked with black or a shade of blue and features a minus sign (-). The following points detail the characteristics that help in identifying a negative terminal: Color: The negative terminal is generally black.
The color red and the plus sign for the positive terminal, and the color black and the minus sign for the negative terminal. The negative terminal connects to the vehicle's metal chassis. In this post, I'll show you clearly which terminal is which, how to fit a battery, and what to do if you connect it back ways.
Car battery terminals will be marked and color-coded. The color red and the plus sign for the positive terminal, and the color black and the minus sign for the negative terminal. The negative terminal connects to the vehicle's metal chassis.
Each step in the maintenance process relies on proper identification to ensure vehicle safety and reliability. A car battery has two terminals. The positive terminal is red and marked with a plus sign. The negative terminal is black and marked with a minus sign.
These are the most critical settings that need to be done carefully for the better functioning of the solar charge controller. A solar charge controller is capable of handling a variety of battery voltages ranging from 12 v. While you set up your new solar charge controller, you should begin with properly wiring the controller to the battery bank and solar panels properly. Once the wiring is properly done an. After the solar charge controller settings for a 12V system, the 24V system is the most common charge controller used in residential solar power systems. The basic settings for this a. Before you begin setting up your lithium batteries, remember that lithium batteries do not require temperature compensation. Also, if you are replacing lead batteries with lithium batteries. The lead acid battery is a classic configuration in a solar power system. Once you convert the battery type from lithium/AGM to lead acid battery, the original set para.
[PDF Version]A solar charge controller is capable of handling a variety of battery voltages ranging from 12 volts to 72 volts. As per the basic solar charge controller settings, it is capable of accommodating a maximum input voltage of 12 volts or 24 volts. You need to set the voltage and current parameters before you start using the charge controller.
When it comes to solar charge controller voltage settings there are several voltages involved: Charging Voltages Charge: The Bulk charge Stage consists of approximately 80% of the charge volume, where the charger current remains constant (in a constant current charger) and the voltage increases.
Set the absorption charge voltage, low voltage cutoff value, and float charge voltage according to your battery's user manual. Adjusting these settings helps prevent battery damage and promotes efficient charging. Start Charging: Your solar charge controller is ready to go once all these settings are adjusted!
In addition to lead-acid and lithium, Morningstar solar charge controllers can also charge nickel, aqueous hybrid ion, and flow or redox flow batteries. Solar charge controllers put batteries through 4 charging stages: Bulk, Absorption, Float, and Equalization. Read more today.
Solar charge controllers put batteries through 4 charging stages: What are the 4 Solar Battery Charging Stages? For lead-acid batteries, the initial bulk charging stage delivers the maximum allowable current into the solar battery to bring it up to a state of charge of approximately 80 to 90%.
Solar charge controllers have different settings that need to be adjusted in order for them to work properly. They set up the output parameters of the power so that the battery bank can be charged at the most optimal voltage.
Published 10 days after a fire at Vistra's 300-MW battery installation near Santa Cruz, the California Public Utilities Commission's proposal would set new standards for energy storage facilities.
For Immediate Release: October 24, 2023 SACRAMENTO — New data show California is surging forward with the buildout of battery energy storage systems with more than 6,600 megawatts (MW) online, enough electricity to power 6.6 million homes for up to four hours.
Long-duration energy storage can currently provide power for up to 100 hours. California has more than 13,300 MW of battery storage installed today. Within the past six years, the state has grown its battery storage capacity by more than 15 times, up from just 770 MW in 2019.
California has more than 13,300 MW of battery storage installed today. Within the past six years, the state has grown its battery storage capacity by more than 15 times, up from just 770 MW in 2019. The recent surge in battery storage has significantly enhanced California's ability to maintain grid stability during extreme weather.
SACRAMENTO – California is boosting battery storage projects across the state – an important part of the state's transition to 100% clean electricity. California today approved a $42 million grant to International Electric Power to build a long-duration energy storage project at Marine Corps Base Camp Pendleton in San Diego County.
In the wake of a spate of fires at battery storage facilities across the state, the California Public Utilities Commission will soon vote on establishing new standards for maintaining and operating them. If passed, the proposal also increases oversight for emergency response at energy storage sites that use batteries.
Battery storage facilities are considered a vital piece of California's target to derive 100% of its electricity from carbon-free sources by 2045 or earlier. Commonly stacked in rows within enclosures, batteries take electricity that's generated during the daytime hours from solar, store that energy and send it to the electric grid in the evening.